Possible Solution: Not enough memory, or your symptom sounds like a problem with registering the charting control used by Energy-10. Try reregistering the control on your system as follows:
1. Determine if a copy of OLCH2X32.OCX has been loaded on your system. (Typically it will be in your "Windows\System" or "WINNT\System32" directory.)
2. If found in System directory, type at the "START\RUN" window REGSVR32 /OLCH2X32.OCX (where is whatever path string applies)
If found but not in "System" directory, put a copy in the system directory and then type command for REGSVR32 as above.
If not found on your system, retrieve a copy from the installation CD and place in your "System" directory and register as above.
If the DLL registration process is successful, you should see a dialog reporting that fact.
http://www.sbicouncil.org/forum/showthread.php?t=24&goto=nextnewest